TOPOWER TP01 Series are modular design hot runner controller , it support 1-16 zones, cavity hot runner system. TP01 hot runner temperature control is international standard which compatible with most brand hot runner module. Also TP01 is multifunctional series which has kinds of protection and detection functions.

Temp Control Precision: +/-1%

Repeat Temp Control Precision:+/-0.1%

Temp Control Stable Precision: +/-1%

T/C Cold Junction Compensation: ≤+1°C

Temp Coefficient K Type 45-450C, J Type 45-450°C

Thermocouple Type :J type or K type

Temp Unit:°C/°F

Control Mode: PlD /PlDD Digital Control

Sampling Frequency:10HZ(100ms)

Thermocouple End Compensation: Dynamic Tracking

Work Mode:Auto/ Manual/Standby

Input Power: Three Phases Five Wires(380VAC)/ Three Phases Four Wires(220VAC)

Temperature Control Module WorkPower:100-240VAC

Frequency:50-60HZ

Single Zone Output Power:3600Max(240VAC)

Single Zone Output Current: 15AMAX(240VAC)

Application Ambient

Relative Humidity: 10%-90%RH, Non-corrosive, No Strong Electromagnetic Radiation Occasion

Ambient Temperature:0-55°C

Transport And Save Ambient Temperature Range:-40-70°C






TP01-4 Zone Hot Runner Controller Main Feature


 Input Power Indicator:

Display the current input power to avoid the error input damage.

Tool-free Quick Disassembly Screws:

SUS304 material screws , not need tool to assemble it.

Technical Grade Hinge Design:

Humanize design to convenient service.

Build-in Removable Dust-proof Screen:

Good radiating to prolong the service life.

Senior Protective Device:

It could add the senior protective device in output part and avoid the loss of load error.(Optional)




TP01-4 Zone Hot Runner Controller Function,Dimension And Weight


  o Adapter FUZZY PlDD Control Technical

  o Automatic Ambient Temp Linear Compensation

  o Electric Current And Output Ratio Display

  o Auto/Manual Work Mode

  o Overload Protect Function

  o Thermocouple Fault Detection

  o Heater Fault Detection

  o SCR Temp Detection

  o SCR Fault Detection

  o Max Current Limitation

  o Overload Protect Function

  o Softstart Time&Output Percentage Adjust

  o Supply Power Frequency Monitor

  o Inner Temperature Detection





TP01-4 Zone Hot Runner Controller Package

The product is securely stabilized with an inner foam box to prevent any movement, while the exterior is protected with a reinforced wooden export crate. This dual-layer packaging ensures that the item remains intact and undamaged throughout sea transit,providing maximum protection against impacts and external pressure.


More Product

Let's do more together

Lorem ipsum dolor sit amet consectetur adipisicing elit.

Get In Touch!

Welcome to contact us.
We will contact you within 24 hours. If urgently, you can send email to us. sales@topower-controller.com.